Seastar Solutions Optimus 360 User Manual Page 64

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 63
© 2012 Teleflex Marine, Inc. Optimus 360 Users Manual, Rev. A
58
10.2.4 System Fault Handling – Example
The following is an example of how the system would respond to the
warning fault hazard of a low port engine battery.
The CANtrak display will enter the warning screen mode and pulse
the system warning buzzer. The three warning screen zones will
appear as shown below.
In this case, the CANtrak tells the user to power off any non
essential devices and to seek technical support as fault handling
instructions. It also informs the user that the system has switched
to the starboard battery and reduced the steering speed.
The vessel should be returned to port immediately for repair.
Active Fault
Description Zone
Fault Handling
Instructions Zone
System Status Zone
This area shows the
active faults
Tells the User how
to proceed
Describes what system has
done to react to fault
10.2.5 CANtrak Loss of Display
In the event of a loss of CANtrak display operation proceed as
follows:
1.
On a multiple helm station vessel each station should be
equipped with a CANtrak display. Proceed to navigate from
another helm station and immediately return to port for service.
2. If there are no secondary displays on board, at low speed
carefully verify that the steering system and shift and throttle
operates normally then immediately and cautiously proceed to
port for service.